6HWWLQJV<RX&DQ&KDQJHZLWK8VHU7RROV
67
❖
❖❖
❖ 3DQHO2II7LPHU
Set the amount of time the machine waits before switching the panel off after
copying has finished or the last operation is performed.
1RWH
❒
Default: 1 minute
❒
The warm up time for making a copy from standby mode is 5 seconds.
❒
The interval time can be set from 10 seconds to 240 minutes using the
number keys.
❖
❖❖
❖ 6\VWHP$XWR5HVHW7LPHU
The System Auto Reset Timer setting automatically switches to the screen of
the function set in Function Priority. This happens if no operations are per-
formed or when an interrupted job is cleared. This setting sets the system re-
set interval. See p.62 “Function Priority”.
1RWH
❒
Default: 60 seconds
❒
The time can be set from 10 to 999 seconds in 1 second increments using
the number keys.
❖
❖❖
❖ &RSLHU'RFXPHQW6HUYHU$XWR5HVHW7LPHU&RSLHU'RFXPHQW6HUYHU
Specifies the time to elapse before copier and Document Server functions are
reset.
1RWH
❒
Default: 60 seconds
❒
If “OFF” is selected, the machine will not automatically switch to the user
code entry screen, and you will not be able to restrict who uses the ma-
chine.
❒
The time can be set from 10 to 999 seconds in 1 second increments using
the number keys.
❖
❖❖
❖ 6FDQQHU$XWR5HVHW7LPHU6FDQQHU
Specifies the time to elapse before the scanner function is reset.
1RWH
❒
Default: 60 seconds
❒
If “OFF” is selected, the machine will not automatically switch to the user
code entry screen, and you will not be able to limit who uses the machine.
❒
The time can be set from 10 to 999 seconds in 1 second increments using
the number keys.