LED DISPLAY
A265/A267 6-2 SM
Code Description Required Action
1Cxx Option bus B (CN507) error
Check the connection to the optional
component at CN507.
Try replacing the optional NIB or HDD.
2100 NIB self test failed.
Turn off the machine and turn it back
on. Replace the NIB if this error is
frequent.
21xx NIB error
2501 The data in the PS DIMM is
damaged.
Replace the PS DIMM if this error is
frequent.
2508
The data in the IC card is
damaged.
Reprogram the IC card and try again.
3003
or
3004
A damaged cluster was found on
the HDD.
The damaged cluster is automatically
marked as “bad”.
If this error is frequent, format the HDD.
47xx Controller ASIC error. Replace the controller.
6.3 LED DISPLAY
6.3.1 LOCATION
The controller uses two LEDs to display error status even while the LCD message
is not active.
LED 1
LED 2
B306T501.WMF
⇒
Rev. 03/2000