C264 Product Support Guide
Installation Requirements
Power Connection
Securely connect the power cord to a power source.
Make sure that the wall outlet is near the machine and easily accessible.
Make sure the plug is firmly inserted in the outlet.
Do not pinch the power cord.
Avoid multi-wiring.
Power Source: 120 V, 60 Hz
The required wall outlet for the C264 is a NEMA 5-15R receptacle.
Installation Times
Unit Installation Time (Minutes)
C264 (mainframe)
20 to 30
Color Drum Type 45R (L)
5
Black Drum Type 45R (S)
5
DF Unit Type 85
15
Platen Cover Type 1018
10
Printer Unit VC-20
30
Interface Board Type 45
20
Tape Dispenser Type 20
10
Machine Space Requirements
Place the machine near a power source, providing clearance as shown below. This machine has a paper
delivery table with buffer fins, so the width of the paper delivery table is changed from 136 cm (previous
model) to 137 cm (this model).
More than
60cm
137cm
Paper
Delivery
Table
More than 10cm
70cm
Paper
Feed
Table
More than
60cm
More than
60cm
Version 1.1 Page 15 of 20