C264 Product Support Guide
Master Type
Thermal master roll type:
320 mm width, 110 m/roll (A3 master roll)
Yield:
200 masters/roll (A3 Drum)
315 masters/roll (A4 Drum)
Maximum run length per master: 4,000 prints
Master Storage
Conditions
Temperature:
0 °C to 40 °C
Humidity:
10% to 95% RH
Recommended maximum storage period:
One year after production date
Note: Avoid locations exposed to direct sunlight.
Ink Type
600 ml cartridge type
Available colors:
Black, Red, Blue, Green, Brown, Purple, Yellow, Navy, Maroon, Orange,
Teal, and Gray
Ink Storage Conditions
Temperature:
-5 °C to 40 °C
(Optimal conditions: 15 °C to 25 °C)
Humidity:
10% to 95% RH
(Optimal conditions: 20% to 70% RH)
Recommended maximum storage period:
18 months after production date
Note: Avoid locations exposed to direct sunlight.
Optional Equipment
• Platen cover
• Automatic document feeder
• A3 color drum
• A4 black drum
• Tape dispenser
• Key Counter (locally acquired)
• Interface kit (to connect the VC-20)
C600 (ADF) Specifications
Original Size
Standard Size (Single-sided Mode only): A3 to A5, DLT to HLT
Non-standard Size (Single-sided Mode only): Max. width 297 mm
Min. width 105 mm, Max. length 1,260 mm, Min. length 128 mm
Original Weight
40 ~ 128 g/m
2
(10 ~ 34 lbs.)
Table Capacity
50 sheets (80 g/m
2
, 22 lbs.)
Original Standard
Position
Center
Separation
FRR
Original Transport
Roller transport
Original Feed Order
From the top original
Reproduction Range
50 ~ 200%
Power Source
24 & 5 VDC from the copier
Power Consumption
25 W
Dimensions (W x D x H)
550 mm x 470 mm x 130 mm
Weight
9 kg or less
Version 1.1 Page 6 of 20