PRINTER ENGINE SC CODES
G031/G032 7-8 SM
SC544: Fusing Low Temperature Error
Definition:
A fusing temperature of lower than 100
°
C is detected for 1 second by the
fusing thermistor (this error does not apply when the machine is in energy
saver mode).
Possible causes
•
Fusing thermistor defective
•
Power supply unit defective
SC998
:
Fusing Unit Mismatch
Definition:
The fusing unit for a different area is installed in the machine.
Possible causes
•
Wrong fusing unit
SC999: Communication Error
Definition:
Communication error between engine and control board.
Possible causes
•
Command error or parity error between engine and control board.