
DIAGNOSTIC ERROR CODES
G031/G032 7-16 SM
Device. Code Description Possible Cause
1401 Initialization error
1402
Empty interrupt request error of the ASIC in
RS232C mode
1403 Empty interrupt request error of the
VR4300 in RS232C mode
1404 Empty interrupt start error of the VR4300 in
RS232C mode
1405 Empty interrupt masking error of the in
RS232C mode
1406 DSR error
1407 Command timeout error
RS232C
1408 Loopback error
Optional RS232C
defective
Printer Control Board
defective
Device. Code Description Possible Cause
1501 Unidentified or unsupported device in the
right option slot
Optional device in the
right option slot
defective
Option Error
1502 Unidentified or unsupported device in the
left option slot (only G031)
Optional device in the
left option slot defective
Comentários a estes Manuais