Savin SDC306 Instruções de Operação Página 24

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 54
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 23
Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 24 -
Display
Parameters
Value
Meaning Value range
Factory
setting
C 0000
Code entry to activate facility to edit 0000 - 9999 0000
00 0
Activate factory setting/reset 0 - 1 0
01 1
Select configuration 1 19 1
10 120
Maximum collector temperature 90°C15C 12C
11 1
Priority storage cylinder
1 cylinder 1
2 storage cylinder 2 / swimming pool
1 2 1
20 0
Mode yield metering
0 off
1 yield estimation
2 yield metering
0 - 2 0
21 0.0
Volume flow (internal value) 0.0 50.0 l 0.0 l
22 0.25
Flow meter 0.050.0 l/min 0.25 l/min
23 1
Glycol type
1 - Tyfocor L5.5
2 - Tyfocor LS, ready mix
3 - Dowcal 10
4 - Dowcal 20
5 - Dowcal N
1 5 1
24 40
Glycol percentage 0% - 100% 40%
30 10
Tolerance
for solar yield 0K 80K 10K
40 1
Period for anti-Legionnaire’s disease
function
1 or 7 days 1
50 1
Circulation mode
1 thermal circulation
2 impulse-controlled circulation
1 2 2
51 5
Power-on time for circulation 1 15 min 5 min
52 5
Restart interlock
for circulation 1 10 min 5 min
60 60
Minimum temperature for boiler 15°C90°C 6C
61 90
Maximum temperature for boiler 30°C 130°C 90°C
70 50
Maximum temperature for sink 3C 70 °C 5C
CodE ----
Change to code 0000 - 9999 ----
The value range “Tolerance for solar yield”
and the lower limit of the value range “Start
temperature for auxiliary heating” are
interdependent. This means that the value
for “Start temperature for auxiliary heating”
cannot be changed so as to be lower than
that for “Tolerance for solar yield”. Equally,
the value for “Tolerance for solar yield”
cannot be changed so as to be higher than
that for “Start temperature for auxiliary
heating”.