11.7 Basic system diagram 7:
1 collector array, 1 storage cylinder, auxiliary heating, return line monitor
System 7 has one collector surface, one
storage cylinder, one auxiliary heating
function and one return line monitor. The
control unit controls the solar function
(temperature difference regulation), the
auxiliary heating (thermostat, timeframe)
and the return line monitor (temperature
difference regulation). Heat metering is also
possible, e.g. using an impeller flow meter.
Information Program Manual operation Basic setting
I I I I
Current collector temperature (E1) Timeframe R2 start Pump A1 off/on Code entry
Minimum collector temperature (E1) Timeframe R2 stop A2 off/on Reset/factory setting
Maximum collector temperature (E1) Maximum temperature of
storage cylinder
A3 off/on Select basic
configuration
Current storage temp. at bottom (E2) Solar circuit Td start A4 off/on Max. collector temp.
Minimum storage temp. - bottom (E2) Solar circuit Td stop Mode yield metering
Maximum storage cylinder
temperature at bottom (E2)
Start temperature, auxiliary
heating
Volume flow
∗
Current storage temp. at top (E4) R3 Td start
DFG/WMM
∗∗
Minimum storage temp. at top (E4) R3 Td stop
Glycol type
∗
Maximum storage temp. at top (E4) Set time
Glycol percentage
∗
Current storage temp. at centre (E3) Tolerance for solar yield
Minimum storage temp. at centre (E3)
Code change
Maximum storage cylinder
temperature at centre (E3)
Current return line temperature (E5)
Minimum return line temperature (E5)
Maximum return line temperature (E5)
Flow rate
∗
Daily yield
∗
Total yield
∗
∗ Displayed only if yield metering mode is equivalent to 1 or 2.
∗∗ Displayed only if yield metering mode is equivalent to 2.