Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 44 -
11.13 Basic system diagram 13:
1 collector array, 1 storage cylinder, swimming pool, auxiliary heating
System 13 has one collector surface, one
storage cylinder, one swimming pool and
one auxiliary heating function. The control
unit controls the solar function (temperature
difference regulation for storage cylinder
and swimming pool, priority logic), and the
auxiliary heating (temperature difference
regulation, timeframe). Heat metering is
also possible, e.g. using an impeller flow
meter.
Info Program Manual operation Basic setting
I I I I
Current collector temperature (E1) Timeframe R2 start Pump A1 off/on Code entry
Minimum collector temperature (E1) Timeframe R2 stop A2 off/on Reset/factory setting
Maximum collector temperature (E1) Maximum temperature of
storage cylinder
A3 off/on Select basic
configuration
Current temperature of storage
cylinder 1 at bottom (E2)
Solar circuit Td start A4 off/on Maximum collector
temperature
Minimum temperature of storage
cylinder 1 at bottom (E2)
Solar circuit Td stop Priority storage cylinder
Maximum temperature of storage
cylinder 1 at bottom (E2)
Maximum temperature
Swimming pool
Mode yield metering
Current temperature of storage
cylinder 1 at top (E3)
Solar circuit pool Td start
Volume flow
Minimum temperature of storage
cylinder 1 at top (E3)
Solar circuit pool Td stop
DFG/WMM
∗∗
Maximum temperature of storage
cylinder 1 at top (E3)
Start temperature, auxiliary
heating
Glycol type
Current swimming pool temp. (E4) Set time
Glycol percentage
Minimum swimming pool temp. (E4) Tolerance for solar yield
Maximum swimming pool temp. (E4)
Code change
Flow rate
Daily yield 1/2
Total yield 1/2
Displayed only if yield metering mode is equivalent to 1 or 2.
∗∗ Displayed only if yield metering mode is equivalent to 2.