11.14 Basic system diagram 14:
2 collector arrays, 1 storage cylinder, auxiliary heating
System 14 has two collector surfaces, one
storage cylinder and one auxiliary heating
function. The control unit regulates the solar
function (temperature difference regulation
for 2 collector arrays) and the auxiliary
heating (thermostat, timeframe). Heat
metering is also possible, e.g. using an
impeller flow meter.
K1 = Collector array 1
K2 = Collector array 2
Information Program Manual operation Basic setting
I I I I
Current collector temperature (E1) Timeframe R2 start Pump A1 off/on Code entry
Minimum collector temperature (E1) Timeframe R2 stop A2 off/on Reset/factory setting
Maximum collector temperature (E1) Maximum temperature of
storage cylinder
A3 off/on Select basic
configuration
Current storage temp. at bottom (E2) Solar circuit Td start A4 off/on Max. collector temp.
Minimum storage temp. - bottom (E2) Solar circuit Td stop Mode yield metering
Maximum storage cylinder
temperature at bottom (E2)
Start temperature, auxiliary
heating
Volume flow
∗
Current storage temp. at top (E3) Set time
DFG/WMM
∗∗
Minimum storage temp. at top (E3)
Glycol type
∗
Maximum storage temp. at top (E3)
Glycol percentage
∗
Current collector 2 temperature (E4) Tolerance for solar yield
Minimum collector 2 temperature (E4)
Code change
Maximum collector 2 temperature (E4)
Current collector flow temp. (E5)
Minimum collector flow temp. (E5)
Maximum collector flow temp. (E5)
Flow rate
∗
Daily yield
∗
Total yield
∗
∗ Displayed only if yield metering is active.
∗∗ Displayed only if yield metering mode is equivalent to 2.